Pouring platforms with single brackets
Preconditions for use: |
---|
Only fix the pouring platform onto formwork constructions that are sufficiently stable to transfer the expected loads. |
Shore the formwork in a windproof manner when erecting it and when it is temporarily placed in the standing position. |
Ensure that the formwork gang has sufficient stiffness. |
Observe all applicable safety regulations. |
|
NOTICE Multi-panel gangs without an opposing formwork and with pouring platforms and Plumbing struts 260 must be fixed on the ground so that they cannot be dislodged. This can be done in either of 2 ways: ▪ with Frami floor fixing plates and Doka Express anchors 16x125mm ▪ using Doka Express anchors 16x125mm placed through the cross boreholes of the Frami Xlife panels |
Note:
The plank and board thicknesses given here comply with the C24 category of EN 338.
Observe all national regulations applying to deck-boards and guard-rail boards.
.